Matrix E5x Specifikace Strana 26

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 25
22
HIGH OR NO RESISTANCE
POSSIBLE CAUSES:
1) The console cable is damaged or not properly plugged in.
2) The UCB is damaged.
3) The Generator is damaged.
4) The LCB is damaged.
SOLUTION:
1) Check the console cable connections at the UCB and LCB.
2) Check if the generator is outputting variable power:
a. Insert the probes from a multi-meter into the black and red wires on the generator wire harness connector (Figure A).

RPM.
3) If the generator does not have variable power, replace the generator.
4) If the generator does have variable power, replace the LCB.
FIGURE A
7.7 TROUBLESHOOTING - RESISTANCE ISSUES
CHAPTER 7: TROUBLESHOOTING
Zobrazit stránku 25